Two innovative solutions make it possible to install a lifting system without pipework above the backwater level
Text KESSEL en Wouter PolspoelImage KESSEL

A wastewater lifting system traditionally requires a backwater loop above the backwater level. It also needs a separate pipe through the roof to supply and extract air. This can involve significant building work, particularly in renovation projects. KESSEL, a specialist in drainage solutions, has developed two solutions, CleverLoop and CleverVent, that enable both backwater protection and ventilation below the backwater level. This means the entire system can be kept in the installation room.
A correctly installed lifting system must prevent wastewater from entering the building when the sewer backs up. To achieve this, the discharge pipe is normally routed in a backwater loop above the backwater level. The system also requires a separate pipe through the roof for ventilation.
In new-build projects, this can generally be taken into account at the design stage. The situation is different in existing buildings. Penetrations through ceilings and roofs may require work on the load-bearing structure and measures to ensure acoustic insulation and fire safety. With CleverLoop and CleverVent, KESSEL aims to eliminate these pipe runs. According to the manufacturer, the solutions are a world first: for the first time, both backwater protection and ventilation for a lifting system can be installed entirely below the backwater level.

Mechanical separation to prevent backwater
CleverLoop takes over the function of a conventional backwater loop using a mechanical system separator between the discharge and collection pipes. While the pump is running, the flow of water automatically opens the flow valve. When the pump stops, the mechanical valve closes automatically. If the sewer backs up, a float provides an additional seal.
The system separator has a modular design. Using sockets and wedges, it can be adapted to discharge pipes from DN 50 to DN 100 and collection pipes from DN 90 to DN 200. An integrated maintenance opening allows access to the component without tools.

Ventilation via the collection pipe
CleverVent addresses the second pipe run. The valve replaces the separate ventilation pipe to the roof. In normal operation, air is exchanged via the collection pipe and the sewer. If backwater occurs, the rising water lifts an integrated float, closing off the connection to the sewer. The system then switches mechanically to ventilation into the room via an activated-carbon filter. According to KESSEL, this principle also works during a power cut.
This component is also integrated directly into the collection pipe. No additional riser pipe is needed, and components requiring regular maintenance, including the activated-carbon filter, remain accessible.
“With the CleverLoop system separator and CleverVent ventilation valve, we are addressing the key challenges of backwater protection, ventilation and installation effort,” says Joachim Ziob, product manager at KESSEL. He also notes that the solutions reduce installation costs by up to 70%.
The benefits of CleverLoop and CleverVent are therefore most evident in renovation projects, but according to KESSEL, the solutions are also suitable for new-build projects in both residential and commercial buildings.

Technical framework developed
As no specific standard existed for these solutions, KESSEL worked with scientific partners, testing bodies and standardisation organisations to develop a technical framework for their use. This resulted in DIN SPEC 3615.
CleverLoop and CleverVent were also extensively tested by TÜV Rheinland and received the ‘Tested by TÜV’ label. The Österreichisches Institut für Bautechnik (OIB) and Swiss certification body Qplus also granted the relevant approvals and certifications. KESSEL supplements this documentation with a manufacturer’s declaration.
Een zakelijke vraag aan Kessel? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- ThemeSafe and efficient water use
- SubjectProduct information
- CompanyKessel