Some habits in public toilets should not be abandoned

Don’t forget Legionella: keep flushing regularly!
The current advice to work from home on a large scale and close public buildings to help prevent the spread of germs and bacteria has implications for drinking water installations. It is especially important to ensure that maintenance of these installations continues. When they are no longer, or only partially, in use, bacteria can easily take hold in the biofilm, a community of micro-organisms that attach to one another and to a surface in contact with water. And regardless of the current situation, we must ensure that good hygiene practices are reinforced and continue in our public toilet facilities in the future.

Legionella bacteria cause Legionnaires’ disease, a respiratory infection that affects people with chronic breathing problems and those with weakened immune systems. The bacteria occur naturally in water and thrive where stagnant water and a source of nutrients are present. They multiply at temperatures of 20-45°C and can be harmful when inhaled as an aerosol. Schools, swimming pools, offices, airports and hospitality venues are examples of public buildings where sanitary facilities are used intensively. During holidays or prolonged closures, drinking water is used little or not at all, which can accelerate biofilm formation in pipes.
Larger commercial buildings often have facilities teams responsible for drawing up and implementing a Legionella prevention plan, but in smaller buildings the responsibility lies with the owners. They, in turn, rely on local expertise to ensure that their installation complies with regulations. The solutions are straightforward: prevent water from reaching temperatures at which bacteria multiply, and limit water stagnation in the installation.
Ring mains or a closed circuit
The applicable regulations identify stagnant water in sanitary installations as a factor that encourages bacterial growth. The use of ring mains, or a closed circuit, is therefore strongly recommended. European standard NF EN 806-5 also states that sections of the installation that are rarely used should be flushed regularly. The recommended interval is once a week. The German guideline Hygiene in Trinkwasser-Installationen VDI/DVGW 6023, issued in April 2013, requires measures to refresh the water after the sanitary installation has been out of use for more than 72 hours.
The Best Available Techniques (BAT) for Legionella control, published in December 2017, state that hot water should be produced at a minimum of 60°C, with a circulation water temperature of 55°C. At this temperature, 90% of bacteria die within 2 hours. If the temperature falls below this guideline, the risk of bacterial growth increases.

Technical solutions in the fight against Legionella
DELABIE is strongly committed to combating and preventing bacterial growth and offers a wide range of technical solutions. A central thermostatic mixing valve, for example, enables the building manager to maintain the prescribed temperatures in the system and ensure user safety. The valve should have anti-scalding protection that ensures the hot water is shut off automatically and immediately if the cold water supply fails, and vice versa. Choosing electronic taps with periodic flushing also prevents water stagnation and, in turn, bacterial growth. Automatic flushing is activated every 24 hours after the last use and flushes for 60 seconds. An anti-stagnation solenoid valve, without a rubber diaphragm behind which a small amount of stagnant water would otherwise remain, is an added advantage in the fight against bacterial growth. Direct-flush toilet systems are also specifically designed for public toilet facilities with high visitor numbers. As the flush is connected directly to the water mains, there is no cistern containing stagnant water, and therefore no limescale or build-up of impurities, meaning there are no elements that promote bacterial growth.
DELABIE’s diverse product range makes it possible to provide a solution for every requirement in public buildings, whatever their purpose or users. DELABIE products are installed at basins, showers, urinals and WCs. The taps are available in various models: deck-mounted, wall-mounted, recessed, or with a service duct for heavy-duty applications, for example.
A business enquiry for Delabie? Get in touch