News

Pressure maintenance units for Canadian zero-emission district heating network

Begin mei zijn de AIR-SEP® drukbehoudstations opgeleverd en in een 40ft High Cube container vanuit de fabriek in Duitsland naar Canada verstuurd.
Begin mei zijn de AIR-SEP® drukbehoudstations opgeleverd en in een 40ft High Cube container vanuit de fabriek in Duitsland naar Canada verstuurd.

After four years of development and preparation, Canada’s capital, Ottawa, is ready to accelerate its move towards a future-proof, zero-emission district heating network. The Energy Services Acquisition Program (ESAP) project will significantly modernise the existing district energy system, which supplies heat to 80 parliamentary and government buildings (total floor area: > 1.83 million m2) and cooling to 67 parliamentary and government buildings (total floor area: 1.73 million m2).

The old steam network in the capital region is the first in North America to make way for an electric system providing cooling and low-temperature hot water for heating. The new energy system will significantly reduce greenhouse gas emissions, phase out ozone-depleting refrigerants and lower the cost of providing essential temperature control to parliamentary and government buildings in downtown Ottawa. The Ottawa River will help cool the water used to provide cooling to all buildings connected to the network. 

Six power plants have been designated to supply heating and cooling: Cliff, Tunney’s, NPB, NRC, RCMP and Confederation Hights. A key component of the energy system is the AIR-SEP® pressure maintenance units from KOREX Benelux, which handle pressure maintenance, vacuum degassing, expansion, dirt separation and system make-up. To achieve this, the units comprise an expansion tank with an inlet valve, vent valve, automatic make-up unit and pressure maintenance pump, which eliminate air bubbles from the pipework. This allows the system water to flow more freely, resulting in greater efficiency, fewer faults and a significantly longer service life for the installations.

Compact, all-in-one expansion unit

The seeds of the Ottawa project were sown back in 2018, when Mario van Gorsel, director of KOREX Benelux, met a major HVAC equipment trading company at the ISH trade fair in Frankfurt. “We had a pleasant conversation, but there were no relevant projects on the horizon at the time,” says Van Gorsel. “That changed in 2020, when the trading company suddenly got back in touch. They were looking for a compact, all-in-one expansion unit that could automatically monitor and perform all functions, including pressure maintenance, vacuum degassing, expansion, dirt separation and system make-up. The AIR-SEP® does this without any problems.”

On the heating side, the RCMP power plant will be connected to 4 AIR-SEP® units, with an expansion water capacity of 2.400 litres (total capacity: 9.600 litres).

First phase

The first phase of the ESAP project involves fitting out the RCMP power plant, with a heating capacity of 18 MW, a heating water capacity of 550.000 litres, a pressure of 2,5 Bar and a total expansion volume of 13.000 litres. “At the beginning of May, we completed the AIR-SEP® pressure maintenance units for this part of the project and shipped them from our factory in Germany to Canada in a 40ft High Cube container,” says Van Gorsel. “There are 6 AIR-SEP® pressure maintenance units connected in cascade. On the heating side, the RCMP power plant will be connected to 4 AIR-SEP® units, with an expansion water capacity of 2.400 litres (total capacity: 9.600 litres). Two AIR-SEP® units have also been supplied for pressure maintenance on the cooling side, with a combined expansion water capacity of 4.800 litres. We have also already supplied 2 AIR-SEP® units for the Tunney’s power plant.”

Unusual temperature profiles

KOREX Benelux is currently busy engineering the AIR-SEP® pressure maintenance units for the Cliff power plant, which has a heating capacity of no less than 120 MW. “One interesting detail of the ESAP project is that the temperature difference between day and night in Canada is many times greater than in the Benelux,” says Van Gorsel. “In the Netherlands, there are only two times a year when all the heating is switched off and on again at the same time, in May and October. In Canada, however, this happens twice a day. It is common there to have cooling during the day and heating at night. Whereas a flow and return temperature of 80/70°C or 70/60°C is usual for heating in the Netherlands, in Canada it is 90/70°C. And while cooling in the Netherlands runs at 12 to 16°C, in Canada the assumed temperature is 4 to 6°C. We take these factors carefully into account in our engineering, ensuring that our installations will also operate perfectly in Canada.”    

Question about this story? Ask your question

Who worked on it

Energy Services Acquisition Program (ESAP) in Ottawa

  1. AIR-SEP® drukbehoudstationsKOREX Benelux

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ProjectEnergy Services Acquisition Program (ESAP)
  • ThemeFossil-free heating and cooling
  • SubjectNews
  • CompanyKOREX Benelux
Share this article

Advertisement

Follow on Installatie & Bouw Vlaanderen

Follow