Aalberts hydronic flow control, a leading industrial player in integrated heating and plumbing solutions, presents NexusValve, a range of static and dynamic balancing valves. The NexusValve range comprises static balancing valves with fixed or variable orifices, dynamic balancing valves and differential pressure controllers, ideally suited to multi-residential and commercial buildings.

Why is balancing so important, and how can systems be balanced?

Without a suitable hydraulic balancing solution, flow rates in a system are often unevenly distributed. This has a negative impact on user comfort and system efficiency. This is usually due to the layout of the circuits: the height of the building, distance from the main pipe, bends and so on.

However, a correctly balanced system offers a number of essential benefits: sustained system performance, improved thermal comfort (uniform heat distribution) and acoustic comfort (no flow noise caused by excessive flow rates), lower energy costs (optimum energy efficiency thanks to better balancing of return temperatures) and more.

NexusValve FLUCTUS is available with female threaded connections from DN 10 to DN 50 and combines two functions in one product: a balancing valve and an isolating ball valve.

With an extensive range of balancing solutions, Aalberts hydronic flow control offers a solution for balancing every circuit. All balancing solutions are manufactured in Europe, specifically in Germany and France. Balancing valves are installed directly at strategic points in the circuit to control the flow rate, usually at the bottom of each riser. Their main function is to adjust the water flow rate so that water flows evenly throughout the system, while also allowing the flow rate to be measured. 

A balancing valve is also a diagnostic tool that can be used at any time to check that the system is operating correctly and easily identify any deviations.

Aalberts hydronic flow control mainly serves multi-residential and commercial buildings. Depending on the type of system, its products fall into two groups: static balancing valves for constant-flow circuits (manual heads, underfloor heating without balancing, and so on) and dynamic balancing valves for circuits with variable flow rates during balancing, mainly due to the presence of
thermostatic equipment.

NexusValve FLUCTUS, a static balancing valve for faster installation and highly accurate measurement

NexusValve FLUCTUS is a fixed-orifice static balancing valve (FODRV) for balancing hydraulic circuits. This versatile balancing valve is compatible with heating and cooling circuits and plumbing applications. NexusValve FLUCTUS is available with female threaded connections from DN 10 to DN 50 and combines two functions in one product: a balancing valve and an isolating ball valve.

Thanks to its integrated Venturi measuring section, which is separate from the balancing section, commissioning is exceptionally quick: the correct flow rate can be balanced in 30 seconds. The flow rate can also be read continuously, regardless of the balancing setting, based on a single Kvm value.

With an extensive range of balancing solutions, Aalberts hydronic flow control offers a solution for balancing every circuit.

In addition, NexusValve FLUCTUS requires no straight pipe length upstream or downstream of the balancing valve to stabilise the flow rate. This flexibility in terms of installation makes fitting even easier.

Simple commissioning saves valuable time during installation, while the ability to shut off the flow without changing the balancing valve setting makes maintenance much easier. Finally, the integrated Venturi measuring section in NexusValve FLUCTUS ensures highly accurate flow measurement, with a tolerance of only around 3%.

Other NexusValve balancing solutions from COMAP-FLAMCO

All NexusValve solutions from COMAP are suitable for heating circuits, cooling circuits and underfloor heating, as well as domestic hot water in the case of static solutions. For static or dynamic balancing, Aalberts Hydronic flow control offers a range of balancing valves.    

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeSafe and efficient water use
  • SubjectNews
Share this article

Follow on Installatie & Bouw Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.