Some habits in public toilets should not be broken

The current advice to work from home on a large scale and close public buildings to help prevent the spread of germs and bacteria has implications for drinking water systems. It is particularly important to ensure that maintenance of these systems continues. When they are no longer in use, or only partly in use, bacteria can easily establish themselves in the biofilm, a community of microorganisms that adheres to one another and to a surface in contact with water. Regardless of the current situation, we must ensure that good hygiene habits are reinforced and maintained in our public toilet facilities in the future.
Don’t forget Legionella: keep flushing regularly!

TEMPOMATIC 4 electronic washbasin tap with automatic periodic flushing prevents water stagnation
Legionella: a public threat
The Legionella bacterium causes Legionnaires’ disease, a respiratory infection that affects people with chronic respiratory problems and those with weakened immune systems. The bacterium occurs naturally in water and develops where stagnant water and a source of nutrients are present, for example in biofilm in pipes or in corroded water storage tanks. It multiplies at temperatures of 20-45°C and can be harmful when inhaled in aerosol form.
Schools, swimming pools, offices, airports and hospitality venues are examples of public buildings with heavily used sanitary facilities. During holidays or prolonged closures, drinking water is hardly used, or not used at all, which can accelerate biofilm formation in the pipes.
Larger commercial buildings often have facilities teams responsible for drawing up and implementing a Legionella prevention plan, but in smaller buildings, the responsibility lies with the owners. They, in turn, rely on local expertise to ensure that their installation complies with regulations. The solutions are simple: prevent the water from reaching temperatures at which bacteria multiply* and limit water stagnation in the installation.

SECURITHERM electronic shower panel with anti-scalding safety
Keep flushing: that’s the message
The bacteriological quality of water in the network must be checked in every public building by taking regular samples and carrying out analyses. Further tests for Legionella in the water are required when levels of > 1,000 colony-forming units per litre (CFU/L) are measured, and remedial measures must be initiated from 10,000 CFU/L.
Current regulations identify stagnant water in sanitary installations as a factor that promotes bacterial growth. Ring mains, or a closed circuit, are therefore strongly recommended. European standard NF EN 806-5 also states that parts of an installation that are rarely used should be flushed regularly. The recommended interval is once a week. The German guideline of April 2013, Hygiene in Trinkwasser-Installationen VDI/DVGW 6023, requires measures to refresh the water after the sanitary installation has been out of use for more than 72 hours.
Drinking water companies therefore advise building managers to continue implementing their Legionella prevention plan properly. Businesses without a Legionella prevention plan, whether mandatory or not, are also advised to flush pipes thoroughly before putting them back into use. This can be done by opening all taps briefly and letting the water run gently for one minute. However, manual flushing is labour-intensive and costly, especially in larger installations.

TEMPOFLUX 3 direct-flush toilet system requires no cistern
Hot, hotter, hottest
The General Requirements for Piped Water Installations (NEN 1006) specify that hot water must be produced at a maximum temperature of 70°C, with a circulation water temperature of 60°C. At this temperature, 90% of bacteria die within 2 minutes*. If the temperature falls below this guideline, the risk of bacterial growth increases.
Complex systems and long pipe runs lead to temperature drops and increase the risk of contamination. To limit this risk, the length of branches to draw-off points should be kept to a minimum. Pipe insulation prevents heat loss and, where cold and hot water pipes run alongside one another, prevents heat transfer. This stops the cold water temperature rising above 20°C, at which point Legionella bacteria are no longer inactive*.

BIOFIL filters provide a temporary solution in the event of bacterial contamination
Technical solutions in the fight against Legionella
DELABIE is strongly committed to combating and preventing bacterial growth and offers a wide range of technical solutions. For example, a central thermostatic mixer allows the building manager to maintain the prescribed temperatures in the network and ensure user safety. The mixer must have anti-scalding protection that automatically and immediately shuts off the hot water if the cold water supply fails, and vice versa.
In addition, choosing electronic taps equipped with periodic flushing prevents water stagnation and, consequently, bacterial growth. Automatic flushing is activated every 24 hours after the last use and flushes for 60 seconds. An anti-stagnation solenoid valve, with no rubber diaphragm behind which a small amount of stagnant water can remain, is an additional benefit in the fight against bacterial growth.
Direct-flush toilet systems are also specifically designed for public toilet facilities with high visitor numbers. As the flush is connected directly to the water supply, there is no cistern containing stagnant water, and therefore no limescale or build-up of impurities. This means there are no elements that promote bacterial growth.
Managing contamination
If water contamination is detected after the installation has been shut down for a prolonged period, point-of-use water filters can be used as a temporary control measure until a permanent, safe solution has been put in place. BIOFIL antibacterial filters, designed for specific applications and with a service life of 2 months, offer peace of mind to both building managers and users. Their innovative hollow-fibre membrane technology microfilters the water. The filters have a large filtration area for higher water volumes and high resistance to clogging, while remaining very compact. These point-of-use water filters are available for both washbasin and shower taps.
The importance of Legionella prevention has long been firmly established on the public health agenda. Reducing the risk of Legionella infection in public buildings presents specific challenges for user safety and system design. By understanding the risks and installing products developed specifically to address these challenges, the risk of contamination and scalding can be readily overcome.
*
| Temperature | Legionella growth |
| <20°C | Dormant |
| 24-45°C | Optimal multiplication |
| 50°C | 90% die within 2 hours |
| 60°C | 90% die within 5 minutes |
Source: Scientific and Technical Centre for the Construction Industry (WTCB: 2002)