New VAV controller delivers accurate measurements at speeds as low as 0.5 m/s

Large air handling units and low air velocities in ducts: these are almost a given today if you want an energy-efficient ventilation system. However, installation space is often limited, and ventilation components often deliver disappointing measurement results at low velocities. These two challenges call for an innovative solution.
According to Trox, a manufacturer of components for the HVAC sector, compact systems and accurate measurements can indeed go hand in hand. “But that means rethinking the measurement principle,” explains Bart Pennewaert, sales director at Trox. “A conventional VAV controller needs a certain length of straight duct upstream to take an accurate measurement, because it uses measuring tubes or sensors. This has two drawbacks: it increases the overall size, and the measurement principle is insensitive to low air velocities or poor airflow conditions. As a result, the controllable airflow range remains very limited.”
Measurement via the damper blade
To measure even the smallest air volumes accurately, Trox set out to find an alternative measurement principle. The new TVE volume flow controller is the first product in the range to measure via the damper blade. “By moving the measurement of the pressure differential to the damper blade, the VAV controller can take accurate measurements at an air velocity of just half a metre per second. At the same time, it continues to measure at duct velocities of up to 13 metres per second.” Another advantage is that the controller is only 31 centimetres long. “As there is no measuring cross, no straight duct length is needed upstream. The TVE is therefore much shorter than other systems, and can be connected directly to the main duct.”
Foolproof system
Sometimes a controller appears not to be working, only for an inspection to reveal that it has simply been installed the wrong way round. The TVE eliminates this human error. “When measurement is taken using a measuring cross, the damper must not affect the incoming airflow. Otherwise, the airflow is disturbed and the measurement is inaccurate. If the controller is accidentally installed the wrong way round, the system will not function properly. But because the TVE does not use a measuring cross, this is no longer an issue with a dynamic transmitter. The controller works perfectly in either direction. It is a foolproof system.”
Patented from the outset
Trox immediately applied for a patent for the innovative measurement principle, which is already being used in VAV controllers with diameters ranging from 100 to 250 mm. The system is ideal for demand-controlled ventilation in offices and residential and industrial applications. For now, it complements the existing range, but Pennewaert is optimistic about the future: “At a later stage, we will also produce larger sizes, enabling us to gradually update the entire range using this technology.”