Mastering efficiency: New control mode delivers better performance

Saving energy costs instead of creating excess pressure: this was Wilo’s main objective when it developed synchronous variable-pressure control (p-v). The new control mode marks a major step forward in view of future Energy Efficiency Index (EEI) requirements.
“By expanding the operating modes already available to include synchronous variable-pressure control, we are optimising the energy efficiency of the entire system. This helps us avoid unfavourable operating conditions,” says product manager Roman Zielinski. “We developed the variable-pressure control mode on the assumption that the pipe friction losses in the system being supplied are positively correlated with the flow rate.” This means that a lower flow rate is likely to require less hydraulic power to compensate for the lower pipe friction losses. Instead of maintaining a horizontal constant-pressure curve, the system follows a straight variable-pressure line as a function of the flow rate. A switch is used to set the gradient of the line, by defining the set pressure at zero flow as a proportion of the set point at maximum flow. The new mode comes as standard on the SiBoost Smart Helix VE, SiBoost Smart MVISE and SiBoost Smart Helix Excel pressure boosting systems.
Optimum combination for energy efficiency
The control mode consists of two parts: variable-pressure control and the synchronous function. Unlike constant-pressure control (p-c), p-v control provides pressure changes that vary linearly with the flow rate, resulting in variable pressure. The lower discharge pressure at partial load requires less power and energy, while also reducing pressure fluctuations at the draw-off points. The new synchronous function, which comes as standard on the multipump systems alongside variable-pressure control, enables the pumps to operate together optimally in terms of overall efficiency and wear. Unlike the familiar ‘Vario’ function, precise speed control is not dependent solely on the peak-load pump, but on all active pumps running at the same speed. “Previously, the pumps were started in stages, which often meant that one pump ran at a lower speed than the others. Running all the pumps at the same speed is not only more energy-efficient, it also requires less power and is more hygienic, because there is no longer any movement at minimum speed when there is no flow,” says Zielinski. Depending on the number and type of pumps, variable-pressure control can reduce the EEI by 9 to 11%. Synchronous operation delivers a further reduction of 5 to 7%. The total reduction of around 16% marks a major step towards future efficiency requirements in the European and international markets. An average energy saving of 16% represents a significant economic and environmental benefit. In addition, the new operating mode minimises noise and vibration: “Tests with the new control mode showed that we were able to reduce vibration in the factory, which naturally means less wear on the components,” explains the Wilo expert. “The noise level during operation is also significantly lower, which is welcome because the pumps have to run at maximum speed much less often.”
Stay in control with Wilo Assistant
Pipe friction losses vary from one building to another, so the control curve needs to be set differently too. The Wilo Assistant app and its integrated ‘Set-up optimiser SiBoost’ tool make it easy to calculate the percentage of pressure at zero flow in relation to the resulting required nominal pressure. This is usually 75 to 95%. We will publish an introduction and concise instructions in the first quarter of this year. Wilo Assistant brings high-efficiency pump technology to the smartphones and tablet PCs of HVAC installers and TGA planners. The free Wilo Assistant app is a user-friendly aid for planning, customer advice and installation.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- SubjectNews