For energy-efficient data centre management

For energy-efficient data centre management

Research confirms that energy efficiency in new data centres has increased by around 60%. This is good news, but it does come with an important caveat. Growing IT capacity means energy demand continues to rise. Data centre managers must therefore keep energy optimisation at the top of their priority list. With its extensive range of Liquid Cooling Package (LCP) Inline DX, Inline DX/FC and CW units, Rittal is making an essential contribution to the creation of energy-efficient data centres.

LCP Inline DX
Previously, Rittal offered the LCP Inline DX only with a capacity of 12 kW. The range has now been expanded with 20 kW and 35 kW versions. The LCP is installed alongside a row of interconnected IT racks. At the rear, it draws in warm air from the room or the Hot Cube, cools it through powerful, compact heat exchangers, then blows it into the Cold Cube at the front. The heat removed is released into the surrounding environment by the external condenser.

Key benefits:

  • maximum energy savings thanks to EC fan technology and IT-focused control,
  • a speed-controlled compressor matches cooling capacity optimally to actual demand,
  • a redundant temperature sensor is integrated as standard on both air sides,
  • low pressure loss on the air side keeps the power consumption of the fan, temperature monitoring and control to a minimum.

“Rittal’s new LCP DX chillers make it possible to save energy in data centres without compromising on quality,” says Olivier Arnold, Managing Director of DATA-Z sprl in Villers-la-Ville. “I like to cite the TV network BeTV as an example. The core business of this pay-TV provider is the distribution of large volumes of multimedia content. The group called on DATA-Z and Rittal to deliver its new data centre. A redundant setup featuring 3 LCP DX units, each rated at 35 kW, was installed with free cooling, delivering significant energy savings without compromising on quality or service.”

LCP Inline DX

LCP Inline DX/FC
A completely new variant is the 35 kW LCP Inline DX/FC, equipped with an integrated refrigerant heat exchanger and an additional water/glycol heat exchanger. By making optimum use of indirect free cooling, it further reduces operating costs. Inverter-controlled pumps and compressors keep power consumption low.

Thanks to an external hybrid condenser using refrigerant, the LCP Inline DX/FC can operate in different modes depending on the required temperature and the outdoor temperature, including indirect free cooling, mixed mode and compressor operation. Switching between these modes is fully automatic.

All variants in the LCP Inline DX and DX/FC ranges can optionally be equipped with humidifiers, dehumidifiers and reheaters, condensate pumps, air filters, and low- and high-temperature condensers.

LCP CW
The new generation of LCP CW (Chilled Water) units features several important improvements that enhance energy efficiency. The 30 kW unit now comes with a new glycol heat exchanger, enabling it to deliver a true 30 kW using a water/glycol mixture (temperature 15°C, glycol concentration 33%). A standard patented droplet eliminator improves condensate management and means the LCP CW can be used in humid environments and at low water temperatures. The new control algorithm also makes the chiller more efficient.
The use of components made from EPP (Expandable Poly Propylene) improves the separation of hot and cold air around the heat exchanger and condensate management. Stainless steel prevents corrosion in this area.

Een zakelijke vraag aan Rittal nv/sa? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectNews
  • CompanyRittal nv/sa
Share this article

Advertisement

Follow on Installatie & Bouw Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.