Heat pump systems are an efficient and environmentally friendly way to heat and cool buildings. However, using heat pump systems presents some specific challenges that need to be taken into account to safeguard the system’s service life and efficiency.

New monobloc installation: considerations and solutions

A new monobloc installation differs from a traditional heating system in several respects. One of the main considerations is the lower flow temperature, which makes a microbubble air vent less efficient. Additional buffer vessels are also often installed to prevent the heat pump from cycling, and these frequently have an unprotected steel inner wall. This often leads to the formation of non-magnetic haematite sludge as a result of oxygen corrosion. The solution is to use chemical protection, such as Fernox F1 Protector. As a precaution, it is recommended to install a non-magnetic Fernox TF1 HP filter. The lower temperature regime also requires a higher flow rate, making larger pipe diameters and low-pressure-drop filter valves necessary, such as those used with a non-magnetic TF1 HP filter with an integrated bypass. Another consideration is the outdoor installation of the heat pump unit, which may freeze in winter if it breaks down or there is a power cut, potentially damaging the outdoor unit. Fernox glycol can be used to prevent this.

Product descriptionFacq No.Fernox No.
TF1 HP Sigma: 22 mm23372662614
TF1 HP Sigma: 28 mm23372762615
TF1 HP Sigma: 1″23372862619
TF1 HP Sigma: 1 1/4″23372962620
TF1 HP Sigma: 1 1/2″23375062621
HP EG Ethylene Glycol 20 L.62595
HP 15 Mono Propylene Glycol 20 L.23372562545
HP 15 c Mono Propylene Glycol 20 L.62546
Express Inhibitor Test: 50 strips 31974962533

Heat pump systems are an efficient and environmentally friendly way to heat and cool buildings. However, using heat pump systems presents some specific challenges that need to be taken into account to safeguard the system’s service life and efficiency.

Hybrid heat pump on an existing system: challenges and solutions

Integrating a hybrid heat pump into an existing system presents specific challenges that need to be taken into account. Renovations often retain part of the heat emitter system, which can mean large amounts of magnetite sludge and other contamination are present, potentially damaging the heat pump. To address this, the system can be cleaned with Fernox F8 Power Cleaner. Use of a Fernox MKIII Flushing Pump is recommended. A magnetic filter, Fernox TF1 Omega / TF1 Sigma, can be fitted on the return to remove residual contamination and magnetite. For complete protection, add Protector+Filter Fluid F9 Expres afterwards.

Although there is no legal requirement to maintain a heat pump system, regular servicing and inspection are strongly recommended. This includes cleaning the Fernox TF1 filter and testing the water with the Express Inhibitor Test strips.

Product descriptionFacq No.Fernox No.
Power Cleaner F8 500 ml84444662487
Powerflow Flushing Machine MKIII70480456874
Powerflushing Filter70480662084
TF1 Sigma Filter 1″32096362591
TF1 Omega 28 mm70083262251
TF1 Omega 1″72496862322
Protector+Filter Fluid Express28442062310
Express Inhibitor Test: 50 strips31974962533

Hybrid heat pump on an existing system: challenges and solutions

Integrating a hybrid heat pump into an existing system presents specific challenges that need to be taken into account. Renovations often retain part of the heat emitter system, which can mean large amounts of magnetite sludge and other contamination are present, potentially damaging the heat pump. To address this, the system can be cleaned with Fernox F8 Power Cleaner. Use of a Fernox MKIII Flushing Pump is recommended. A magnetic Fernox TF1 Omega filter can be fitted on the return to remove residual contamination and magnetite.

Although there is no legal requirement to maintain a heat pump system, regular servicing and inspection are strongly recommended. This includes cleaning the TF1 HP filter and testing the water with the Express Inhibitor Test strips.

In conclusion, using the right chemical protection and filters is essential to maintaining the performance and efficiency of heat pump systems. Following these recommendations and carrying out regular maintenance can prevent problems such as corrosion, contamination, frost damage and inefficiency, extending the system’s service life and improving its performance.

Een zakelijke vraag aan Fernox? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeFossil-free heating and cooling
  • SubjectNews
  • CompanyFernox
Share this article

Advertisement

Follow on Installatie & Bouw Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.