Environmental impact of building services: a new development for TOTEM

Analysis has shown that, from an environmental perspective, improving insulation is preferable to replacing building services. The same analysis also shows, however, that a carefully selected heat pump combined with balanced ventilation can reduce the environmental impact of a new or renovated building.
The TOTEM tool (www.totem-building.be) can now be used to assess a building’s environmental impact, taking account of its building services. We therefore worked with Buildwise to assess two scenarios for a correctly insulated new semi-detached house with a floor area of 175.6 m². In the first scenario, the building is fitted with a gas boiler and a type C mechanical ventilation system without heat recovery. The environmental impact of the building services materials is g75 times higher than that of propane. Regulations are currently being developed to ban certain types of refrigerant. The impact of harmful gases can, of course, also be limited by choosing a system that contains a small amount of gas or by minimising leaks.
Should you prioritise replacing the building services or installing insulation to reduce the environmental impact of an uninsulated building? TOTEM provides the answer.
We apply two renovation scenarios to our example: replacing the building services rather than installing insulation (scenario 3), and fully renovating the building (scenario 4).
In scenario 3, a heat pump and balanced ventilation are installed. Although the environmental impact of energy consumption is greater than it would have been if the building had been insulated, it is lower than if the original gas boiler and mechanical ventilation had been retained in an uninsulated building. However, the building services need to be oversized compared with similar systems in an identical but insulated building, because of the higher energy demand. In addition, installing a heat pump requires modifications to the existing system. Heat pumps operate at low temperatures, which means, among other things, that larger radiator surfaces are needed. These, however, directly increase the environmental impact of the building services.
Scenario 4 involves insulating the external walls and installing a heat pump and balanced ventilation. Although the environmental impact of the materials is greater than in scenario 3, the total impact is lower. Insulation is therefore the preferred strategy for reducing a building’s environmental impact.
This is the abridged version of Buildwise article 2023/04.06, available at www.buildwise.be.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- ThemeFossil-free heating and cooling
- SubjectNews