News

Air handling units with integrated heat pumps: ‘No defrost cycles, efficient, and easier for installers’

‘Zowel de condensor als de verdamper zitten verwerkt in de luchtgroep. Naast de ingebouwde warmtepomp wordt er ook nog energie gerecupereerd via het warmtewiel.’
‘Zowel de condensor als de verdamper zitten verwerkt in de luchtgroep. Naast de ingebouwde warmtepomp wordt er ook nog energie gerecupereerd via het warmtewiel.’

As the direct distributor of Swedish company IV Produkt, AirX is making the case for air handling units with integrated heat pumps.

This unique system combines AirX’s in-depth expertise in ventilation and air handling units. “We take the burden off installers so they can focus on what they enjoy doing, namely installing,” the company says. 

The units are developed and manufactured in Sweden. AirX delivers them to site fully plug-and-play.

AirX focuses on air-side balancing and measuring all ventilation systems, from small installations to office buildings, hotels, schools and more. “We balance all installations as well as possible and provide advice on matters including the positioning of control dampers,” says Dirk Merken, managing director of AirX.

‘This system guarantees a constant temperature of 21 °C without additional coils’

Using expertise to promote ventilation

“All Air Experts have more than 15 years’ experience in the ventilation industry. We want to use this expertise to promote ventilation and take the burden off installers. Every Air Expert has experience in preparing ventilation studies, selecting air handling units to meet project requirements, commissioning installations and visiting sites where problems have arisen. We have also developed expertise in balancing large ventilation systems and are certified Ventilation Reporters and Blower Door Testers.”

‘We take the burden off installers so they can focus on what they enjoy doing, namely installing.’

AirX is also a direct distributor of IV ­Produkt. The Swedish company supplies high-quality air handling units tailored to each project. “IV Produkt developed air handling units with integrated heat pumps as early as 1974: a unique concept,” says Merken. “This means the units can maintain a constant supply air temperature at any outdoor temperature, from -10°C to 30°C, without defrost cycles or pre- and post-heating, and with optimum energy efficiency.”

According to Merken, an air handling unit with an integrated heat pump offers many advantages. “Both the condenser and the evaporator are incorporated into the air handling unit. Alongside the integrated heat pump, energy is also recovered via the rotary heat exchanger.” Its high COP also significantly reduces operating costs. The compressor and rotary heat exchanger together achieve energy efficiency of more than 90 per cent. 

No defrost cycles

IV Produkt’s system stands out from conventional heat pumps, particularly because it eliminates defrost cycles. Merken explains: “Conventional heat pumps freeze up at lower outdoor temperatures, increasing fan power consumption and causing the supply air temperature to drop sharply during defrosting. This system guarantees a constant temperature of 21 °C without additional coils.” The two systems, the heat pump and the air handling unit, work seamlessly together, Merken continues. “Before the air handling unit leaves the factory, the integrated heat pump’s operation is thoroughly tested, as is the unit’s entire control system. As everything is delivered to site as a single unit, one party can commission the ventilation system, and the different components work together efficiently.”

The units are developed and manufactured in Sweden. AirX delivers them to site fully plug-and-play. “If required, we split everything into sections so that the separate parts can fit through a 900 mm doorway. They can then be reassembled using quick couplings and plug-in connectors,” Merken explains. 

No refrigeration work required

“This plug-and-play service saves installers a great deal of time and space. It can also, for example, free up entire roofs from building services equipment, allowing them to be used as terraces or planted with greenery. What is more, everything is pre-assembled and tested at the factory, so installers do not need refrigeration certification, as no refrigeration work is required on site.”

AirX is also running a special offer that highlights its own expertise. “Customers who order both the air handling unit and the system balancing from us now receive a five-year warranty instead of the usual two years,” says Merken. “We help select an air handling unit tailored to the project, and ensure the system runs optimally and a correct measurement report is provided. We also support installers with advice, for example on correctly positioning control dampers. We do all this so installers can get back to focusing on what they enjoy doing, namely installing.”

Een zakelijke vraag aan AirX Air Experts? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeFossil-free heating and cooling
  • SubjectNews
  • CompanyAirX Air Experts
Share this article

Follow on Installatie & Bouw Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.