Cleaners and protectors in the fight against contamination and blockages

Sludge, corrosion or limescale, and blocked boiler heat exchangers can cause all sorts of problems. Replacing a heat exchanger, or even the entire boiler, often seems to be the only solution, but in many cases the problem can be tackled more subtly and with less disruption. “Fernox cleaners and protectors can deliver excellent results,” says Freddy Denies of Verwarming Sanitair Denies in Hoeilaart.

Freddy Denies recalls a customer he helped twelve years ago. “It was my customer’s brother-in-law,” he says. “One or more of the boiler’s heat exchangers had a blockage in one of the channels. Even a small amount of sludge can lead to a blockage. Circulation stops at the point of the blockage, causing a very annoying knocking sound, as if someone were hitting an iron pipe with a hammer. As soon as the customer explained the problem, I knew what was going on.”

Replace or treat
A blocked boiler heat exchanger is a familiar and common problem. “The installer for that customer recommended replacing the boiler, but the customer wasn’t keen. Replacing a heat exchanger is also an option, but you can’t know in advance exactly which one is blocked. Waiting for it to burst is certainly not the best option either. I was already familiar with Fernox products for cleaning and protecting old, contaminated heating systems, and the customer was immediately willing to try them in his system. He also suggested doing it himself, which is perfectly possible.”

Long-lasting results
Fernox Cleaner F3 and Protector F1 were used in the system, and the results spoke for themselves. “The blockage was gone,” says Freddy Denies. “Even I was surprised, because I wasn’t sure it would work. Today, more than twelve years later, the boiler is still running with the same product. So you can certainly call it a long-lasting and sustainable result. I contacted the customer recently, and he is still very satisfied. Fernox can help with more than just sludge in pipes or boiler heat exchangers. Recently, a customer had sludge in the flow pipe. This is rare, but Fernox Cleaner F3, used in combination with Protector F1, solved the problem here too.
Easy to use
Using Fernox Cleaner F3 and Protector F1 is straightforward. Freddy Denies explains: “First, drain the boiler and add Cleaner F3. Then run the heating at a high temperature for about three days. It’s best to open all the valves to clean the entire system. After those three days, drain the water, refill the heating system and, in very contaminated systems, repeat the process once more. This thoroughly flushes the boiler and the entire system. Finally, add Protector F1. This customer’s system has now been running flawlessly for twelve years. For an additional check, there is also a Test Kit, which you can use, among other things, to test whether the heating water is still of the right quality.”