All-inclusive ventilation family with three models

Ventilair Group is launching a new family of all-inclusive units for balanced ventilation with heat recovery (system D), available in three airflow capacities. The Vent-Axia Econiq comes in 300, 450 and 600 m3/h models. These units are fully equipped to control the indoor climate, thanks to two built-in CO2 sensors, room sensors, controls and a free mobile app.
The units are available in three nominal airflow capacities: 300, 450 and 600 m3/h. “The ideal operating points are at 150 Pa, but the unit has some flexibility,” says Steven Braekeveldt, Product and Marketing Manager at Ventilair Group. “All three units can actually handle an external duct resistance of more than 200 Pa. This ensures the required airflow at the valves is always achieved.”

“The units are optimised for EPB, but what matters more is the energy efficiency of the unit as a whole,” Braekeveldt continues. “We achieve efficiency of up to 85% at the nominal airflow capacities, in line with EPB requirements. The unit delivers a constant airflow and has a 100% bypass. The motors also use less energy and run quietly, thanks to the low internal resistance.”

All-inclusive
A wide range of add-ons is available for many ventilation units. The Vent-Axia Econiq units are different. “Other units always start with a stripped-down model that you then build up,” says Braekeveldt. “With the Vent-Axia Econiq, everything is built in: Bluetooth, Wi-Fi, radio frequency, an app, CO2 sensors, 0-10V inputs and Modbus.” Everything is included as standard. “That makes things easier not just for installers and logistics, but for users too.”
“The unit measures CO2, humidity and temperature, and gives users insight into indoor air quality through colour-coded screens in the app.” As well as the mobile app, the unit also has a display that can be used to control it. “Homeowners always know what is happening, and installers can control everything from it. Installers also get an installation wizard and a checklist to check that the installation meets requirements.”

Internal CO2 sensor
The Vent-Axia Econiq units are equipped with two internal CO2 sensors. “That’s unique,” says Braekeveldt. “The installer doesn’t have to do anything. They buy a unit with a built-in CO2 sensor and immediately get an EPB reduction. When CO2 levels are poor, the system ventilates more than when they are good. This also saves energy.” The sensors are always located on both sides, which means the unit is also fully reversible digitally.

Configuration
Ventilair Group’s new family of ventilation units is easy to install, starting with its practical design. “There are top and side connections. The units can be installed in a compact layout, close to the ceiling. And, of course, they can be reversed digitally.”
Configuring the units is also straightforward. “Our back office can prepare a configuration file in CSV format. It is then sent to the person commissioning the system, who can load the configuration onto the unit using their phone,” explains Steven Braekeveldt. “We can also copy functions from one unit to another. That can be very useful in an apartment building, for example.” Finally, Ventilair Group also offers RS485, a mode that allows the module to be controlled via the building management system.
“This unit is part of our complete solution,” concludes Braekeveldt. “Over the past year, we have also launched Uniflexplus+ 69, a low-pressure duct system, a Uniflexplus+ valve, a new range of insulated ducts... We offer installers a ready-to-install solution.”
Een zakelijke vraag aan Ventilair Group? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- ThemeHealthy air and summer comfort
- SubjectVentilation