General

New amendments to the AREI take effect on 1 March 2025

Text Wouter PolspoelImage Pixabay

De aanpassingen omvatten onder andere nieuwe voorschriften rond contactdozen.
De aanpassingen omvatten onder andere nieuwe voorschriften rond contactdozen.

The amendments to the General Regulations on Electrical Installations (AREI), the Belgian legislation governing the installation and use of electrical installations for domestic, commercial and industrial applications, set out in the Royal Decree (RD) of 3 October 2024, take effect on 1 March 2025. They amend all three books of the AREI.

The AREI applies to all new electrical installations. Its provisions must also be followed when renovating or extending existing electrical installations.

Electricians among Installatie & Bouw’s readers will no doubt be familiar with it, but a refresher never hurts, so here is a brief summary of what the AREI covers and its scope. The AREI aims to safeguard the safety of people, property and animals by imposing strict standards on electrical installations, including low-voltage, medium-voltage and high-voltage installations. It sets out requirements to prevent short circuits, overloads and electric shocks. The AREI applies to all new electrical installations, and its provisions must also be followed when renovating or extending existing electrical installations. Installers and owners of electrical installations that do not comply with the AREI, which must be inspected periodically, risk fines and liability in the event of fire or accidents caused by the installation.

Since June 2020, the AREI has been divided into three books, each following the same structure of nine sections. Book 1 sets out the rules for low-voltage and extra-low-voltage electrical installations, Book 2 covers high-voltage electrical installations, and Book 3 lays down the provisions for installations for the transmission and distribution of electrical energy. 

The AREI aims to safeguard the safety of people, property and animals by imposing strict standards on electrical installations.

All three books amended

The AREI has been amended several times by Royal Decree since it was split into three books. A further amendment now follows, set out in the Royal Decree of 3 October 2024, which was published in the Belgian Official Gazette on 28 October. The decree comes into force on 1 March 2025 and amends all three books of the AREI. Here is an overview:

1. Rooms containing a bath and/or shower

  • new specific requirements for electrical installations in these rooms, in Chapter 7.1 of Book 1;
  • impact of new requirements in Book 1 (Subsections 4.2.2.5 a & c and 4.2.4.3 b);
  • derogations in Parts 6 and 8 of Book 1 applicable to existing electrical installations in these rooms, and to non-substantial alterations and extensions carried out in them …;
  • transitional provisions in Chapter 7.1 of Book 1 applicable to projects and works that commenced before 1 March 2025, provided the conformity inspection before commissioning takes place on or after 1 March 2025;
  • repeal of Section 7.2.5 of Book 1 (private swimming pools in domestic installations: application of Chapter 7.2 of Book 1, and therapeutic bathing facilities: application of Chapter 7.1 or 7.2 of Book 1, depending on the type of installation).

2. Publicly accessible spaces

  • addition of a definition in Subsection 2.2.1.1 of Books 1, 2 and 3;
  • standardisation of the term in Books 1, 2 and 3;
  • new requirement concerning the designation of these spaces in the document on external influences for non-domestic installations (Section 9.1.6 of Book 1, Section 9.1.5 of Book 2 and Section 9.1.5 of Book 3);
  • two-year transitional provisions concerning the designation of these spaces, applicable to existing non-domestic installations (Article 60 of the Royal Decree of 3 October 2024).
Installers and owners of electrical installations that do not comply with the AREI risk fines and liability in the event of fires or accidents caused by the installation.

3. Socket-outlets

  • new requirements in Subsection 5.3.5.2 of Book 1 for selecting low-voltage socket-outlets in domestic and non-domestic AC installations:

IP rating
applicable standard
other permitted socket-outlets;

  • derogations in Parts 6 and 8 of Book 1 applicable to existing electrical installations;
  • transitional provisions in Subsection 5.3.5.2 of Book 1 applicable to projects and works that commenced before 1 March 2025, provided the conformity inspection before commissioning takes place on or after 1 March 2025.

4. Other amendments

  • correction of Figure 4.11 (Subsection 4.2.4.3 b of Book 1);
  • clarification of the Dutch text on the local installation of the supplementary equipotential bonding connection (Subsection 4.2.3.2 of Books 1 and 3);
  • addition of a requirement for conformity with the NBN standard for switchgear and distribution boards in publicly accessible spaces (Subsection 5.3.5.1 a of Books 1 and 3);
  • correction of some Dutch terms in Books 1, 2 and 3 (accessible, reinforcement, armouring, cladding);
  • correction of some terms in Book 1 (not included in the Royal Decree of 5 March 2023).

That is quite a list. But, like all previous amendments, the latest changes are intended to make electrical installations even safer. And we can hardly object to that. 

Download the amended books

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectGeneral
Share this article

Follow on Installatie & Bouw Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.